DB-RTVP Rooftop Vent Package

Re-Verber-Ray

(No reviews yet) Write a Review
$145.00
SKU:
DB-RTVP
Adding to cart… The item has been added

Product Overview

Re-Verber-Ray's DB-RTVP is a complete 3-inch rooftop vent package for taking a single low-intensity tube heater straight up through the roof. The kit forms the entire rooftop termination for a single-vented unit: the adapter transitions the heater's B-vent connection to C-vent pipe, the elbow and pipe route the flue vertically, the firestop spacer and adjustable flashing seal the roof penetration, the storm collar sheds water around the pipe, and the vent cap terminates the run above the roofline, with the sealant used at the roof penetration and joints.

There is no separate OEM cross-reference for this kit; it is Re-Verber-Ray's own factory-matched part number for this venting job, not a supersession of an earlier part. It fits the LS3 and LD3 series (3" vent pipe required for single venting), the broader LS and LD series per the general RTVP-3 install sheet, and is listed for the UH-30N and UH-45N per current distributor data; see Fitment below for the full list.

The kit ships as one part number and includes a DB-211 3" B-to-C adapter, DB-RVC 3" rooftop vent cap, DB-FS 3" rooftop firestop spacer, DB-ARF 3" adjustable rooftop flashing, DB-SC 3" storm collar, DB-VE 3" 90° vent elbow, and a tube of RTV-106 high-temperature sealant. Not included is the vent pipe itself: 3" double-wall B-Vent (DB-BVP) or single-wall C-Vent must be ordered separately by the section, per the manufacturer's installation sheet.

Replacing this part: swap in a DB-RTVP when an existing rooftop cap, flashing, or storm collar is failing or the roof penetration is being redone, matching the 3" vent pipe size already run to the heater. Before working on any vent, shut off the gas supply, disconnect electrical power to the heater, verify the replacement against the installation sheet, and have a qualified technician confirm proper venting operation before returning the unit to service. Installation sheet: LSH058 DB-RTVP & RTVP-4 Installation Sheet.

Specifications

Vent pipe diameter3 in.
Kit contentsDB-211 (3" B to C Adapter), DB-RVC (3" Rooftop Vent Cap), DB-FS (3" Rooftop Firestop Spacer), DB-ARF (3" Adjustable Rooftop Flashing), DB-SC (3" Storm Collar), DB-VE (3" 90-degree Vent Elbow), RTV-106 (High Temperature Sealant)
Vent pipe (not included)3 in. B-Vent (double-wall) or C-Vent (single-wall) pipe must be ordered separately; B-Vent offered only as a 60 in. section
Clearance to combustibles1 in. air space clearance required when using B-Vent (Simpson Dura-Vent round B-Vent), regardless of diameter
Vent cap minimum height above roof24 in. min.; consult NFPA ANSI Z223.1 Gas Vent Termination criteria if roof pitch exceeds 9:12
Code complianceInstallation must conform to local building codes or, absent local codes, the National Fuel Gas Code ANSI-Z223.1-1999 (NFPA 54 current edition)
Shipping methodUPS or USPS
Voltage / gas typeN/A (mechanical venting kit; not electrical, not gas-type specific)

Cross-Reference & Fitment

Alternate part numbersRTVP-3
FitsUH-30N, UH-45N, LS Series, LD Series, DBS, LS3-10-25, LS3-10-30, LS3-15-25, LS3-15-30, LS3-15-40, LS3-15-50, LS3-20-40, LS3-20-50, LS3-30-50, UH-30N & UH-45N