RTVP-6 Roof Vent Penetration Package with Cap

Re-Verber-Ray

(No reviews yet) Write a Review
$249.00
SKU:
RTVP-6
Adding to cart… The item has been added

Product Overview

The RTVP-6 is Re-Verber-Ray's complete 6-inch rooftop vent penetration package for common-venting a low intensity tube heater straight up through the roof. It lets the heater's exhaust common-vent vertically through the roof instead of terminating through a sidewall, running double-wall B-vent from the heater up through the firestop spacer, the B-to-C adapter, and the adjustable flashing before exiting through the vent cap. The adjustable rooftop flashing accommodates varying roof pitches, and the RTV-106 sealant with the storm collar keep the roof penetration weathertight.

It fits Re-Verber-Ray's low intensity tube heater line, including the CL3, CX3, DXSB, DXSS, HLSB, HLSS, and SV/SSV series, and is the correct rooftop package for the FA-150 through FA-400 when common venting two heaters; see Fitment below for the full list.

The kit ships with a B-to-C adapter (DHC-6), an adjustable rooftop flashing (ARF-6), a 6-inch vent cap (RVC-6), a 6-inch firestop spacer (FS-6), a 6-inch storm collar (SC-6), a vent elbow (VE-6), a vent tee (VT-6), and RTV-106 high-temperature sealant. Six-inch B-vent (BVP-8 or 18BV-6) and any single-wall C-vent or dual exhaust assembly are not included and must be ordered separately.

When replacing a rooftop vent kit, shut off the gas supply and disconnect power to the heater before disturbing any vent connection, and verify the finished installation against the RTVP-6 installation sheet before returning the heater to service; venting work should be confirmed by a qualified technician. See the RTVP-6 installation sheet for the full rooftop vent requirements, including the required clearance to combustibles and minimum vent cap height.

Specifications

Kit contentsIncludes B to C Adapter (DHC-6), Adjustable Rooftop Flashing (ARF-6), 6" Vent Cap (RVC-6), 6" Firestop Spacer (FS-6), 6" Storm Collar (SC-6), Vent Elbow (VE-6), Vent Tee (VT-6), High Temperature Sealant (RTV-106)
Diameter6 in.
Vent pipe (ordered separately)6" B-Vent (BVP-8 or 18BV-6) not included; must be ordered separately
Code complianceInstallation must conform to local building codes or, absent local codes, the National Fuel Gas Code ANSI-Z223.1-1999 (NFPA54 current edition)
Clearance to combustibles1 in. clearance (air space) to combustible material required when using Simpson Dura-Vent round B-Vent, regardless of diameter
Rooftop vent cap clearance24 in. min. above roof, per Figure 2 (Rooftop Vent Requirements) in the install sheet
VoltageN/A
Gas typeN/A
Shipping methodUPS or USPS

Cross-Reference & Fitment

Alternate part numbers6BVK
FitsAll low intensity tube heaters, FA-150 to FA-400, CL3, CX3, DXSB, DXSS, HLSB, HLSS, SV/SSV, FA-150 through FA-400