Product Overview
The DB-DSK is a complete 3 in. sidewall venting kit that vents combustion byproducts from a single heater out through an exterior sidewall. The DB-211 adapter steps the heater's B-vent connection down to single-wall 3 in. pipe, the DB-210 thimble carries that pipe through the wall opening, and the DB-208 cap with flapper terminates the run outside while maintaining proper static pressure for the unit.
The kit fits Re-Verber-Ray LS3 and LD3 series tube heaters and UH-30/UH-45 unit heaters requiring single sidewall venting, for a venting run of roughly 6 to 9 ft. See Fitment below for the full model list.
As shipped, the kit is 30 in. in length when fully assembled and includes 1 DB-208 sidewall vent cap with flapper, 1 DB-209 double-wall B-vent section, 1 DB-210 wall thimble, 1 DB-211 B-to-C adapter, 3 DB-213 single-wall vent pipe sections, and 1 tube of RTV-106 high-temperature sealant.
When replacing an existing sidewall vent kit, match the vent diameter and run length to the heater series before ordering. Shut off gas and disconnect power to the heater before beginning any venting work. Slope the vent pipe down 1/4 in. per foot toward the outlet, keep the termination at least 36 in. below or beyond any combustible overhang, and seal single-wall joints with high-temperature sealant and sheet metal screws per the installation sheet. Verify the completed installation against the installation sheet and have a qualified technician confirm proper unit operation.
Specifications
| Kit Contents | 1x DB-208 (vent cap), 1x DB-209 (double-wall B-vent), 1x DB-210 (wall thimble), 1x DB-211 (B to C adapter), 3x DB-213 (single-wall vent pipe), 1x RTV-106 sealant |
| Assembled Length | 30 in. when fully assembled |
| Supported Vent Length (product page) | Complete sidewall venting kit for lengths 6 to 8 feet |
| Supported Vent Length (packing list) | 3 in. vent package, complete sidewall venting kit for lengths up to 9 ft. |
| Maximum Overall Vent Length (install sheet) | Maximum vent length is 20 ft. (6 m) |
| Vent Pipe Diameter | 3 in. |
| Shipping Weight | 10 lbs. |
| Voltage | N/A |
| Gas Type | N/A |
| Vent Pitch | Slope vent pipe down toward outlet 1/4 in. per foot of length; do not pitch the heater |
| Clearance to Overhang | Vent must be a minimum of 36 in. below or extend beyond any combustible overhang |
| Sidewall Termination Clearance | 6 in. minimum from sidewall termination per installation figure |
| Sealing Method | Seal single wall vent with high temperature sealant (RTV-106) and three (3) #8 sheet metal screws |
| Code Compliance | Installation must conform to local building codes or, absent local codes, the National Fuel Gas Code ANSI-Z223.1 (NFPA 54 current edition) / National Standards of Canada |
| Required Vent Pipe Size for Fitment | 3 in. vent pipe must be used when single venting LD & LS Series |
Cross-Reference & Fitment
| Fits | LS, LD, DBS, LS3, LD3, UH-30, UH-45, LS3-10-25, LS3-10-30, LS3-15-25, LS3-15-30, LS3-15-40, LS3-15-50, LS3-20-40, LS3-20-50, LS3-30-50, LD3-15, LD3-20, LD3-30, LS 10-25, LS 10-30, LS 10-40, LS 15-40, LS 20-40, LS 15-50, LS 20-50, LS 30-50 |