TP-CPA-2 Center Panel Assembly

Re-Verber-Ray

(No reviews yet) Write a Review
$297.00
SKU:
TP-CPA-2
Availability:
3 - 5 Days
Adding to cart… The item has been added

Product Overview

The Re-Verber-Ray TP-CPA-2 is a complete center panel assembly for DTH(S) Series tube heaters rated 40-100 MBH. The center panel houses the combustion fan and the pressure switches that prove airflow before and during burner operation: the normally open switch confirms the fan is running and pulling adequate draft before the gas valve is allowed to open, and the normally closed switch monitors for a blocked or failed venting condition and shuts the burner down if pressure falls out of range. Together they form the safety interlock that keeps the heater from firing without proper combustion airflow. Installing the TP-CPA-2 converts the heater to a DTH(S)-2 Series configuration.

Fits the DTH and DTHS Series, 40-100 MBH only; see the Fitment panel below for the full model list. The TP-CPA-2 replaces the entire center panel assembly on the heater, including the fan and both pressure switches, superseding the older TP-60 (26-114030-11) fan blower and TP-61 (162804-00) pressure switch used on earlier DTH(S) center panels.

It ships as a complete kit:

  • Center panel
  • TP-55A fan blower
  • TP-264B normally open pressure switch
  • TP-60C normally closed pressure switch
  • 20 in. vinyl sensing tube (cut to length on install)
  • Aluminum pick-up tube
  • Two insect-resistant brass barb fittings

The included pressure switches cross-reference to Cleveland Controls NS2-1068-00 (normally open) and NS2-1239-00 (normally closed).

Before starting, shut off gas to the heater and disconnect electrical supply voltage; do not restore power until the panel is fully installed and wired. Installation requires removing the door switch (if equipped), the six screws holding the old center panel to the control box shell, and the old panel with its fan and pressure switches still attached, then mounting the new TP-CPA-2 panel with the existing screws and rewiring per the included diagram. This is a gas-path and safety-interlock component; installation should be performed or verified by a qualified technician against the installation sheet, and the heater should be cycled to confirm proper operation before returning it to service. Full instructions: TP-CPA-2 Installation Instructions.

Specifications

Voltage N/A
Gas Type N/A
Shipping Method UPS or USPS
Converts Heater To DTH(S)-2 Series
Fan Blower (included) TP-55A Fan Blower, qty 1
N.O. Pressure Switch (included) TP-264B Normally Open Pressure Switch (NS2-1068-00), qty 1
N.C. Pressure Switch (included) TP-60C Normally Closed Pressure Switch (NS2-1239-00), qty 1
Sensing Tube (included) 20 in. Vinyl Sensing Tube, cut to length, qty 1
Pick-up Tube (included) Aluminum Pick-up Tube, qty 1
Brass Barbs (included) Insect Resistant Brass Barbs, qty 2

Cross-Reference & Fitment

Replaces TP-60, TP-61, 26-114030-11, 162804-00
Alternate part numbers TP-CPA2, CPA-2, CPA2, 24KT62
Fits DTH, DTHS

Documents

Warranty Information

90 Days

Reviews

(No reviews yet) Write a Review